How to fix Labtech Card Reader Lid Open Error?
- NNathan GarciaAug 18, 2025
If the Labtech Card Reader displays a 'Lid Open Error', close the lid and start the measurement again.
How to fix Labtech Card Reader Lid Open Error?
If the Labtech Card Reader displays a 'Lid Open Error', close the lid and start the measurement again.
What to do if Labtech Card Reader shows USB timeout?
If you encounter a 'USB timeout' error with your Labtech Card Reader, this indicates a system error. Report this issue to customer support.
What to do if Labtech LT-4500 Card Reader displays Wavelength Not Available?
If the Labtech Card Reader shows 'Wavelength Not Available', this indicates a system error. Report this issue to customer support.
What causes Invalid Wavelength error on Labtech LT-4500 Card Reader?
If the Labtech Card Reader displays 'Invalid Wavelength', this indicates a system error. Report this issue to customer support.
Why does my Labtech LT-4500 show Value Not Set error?
If the Labtech Card Reader displays the error 'Value Not Set', it is due to a system error. Report this to customer support.
What does Lamp Overflow mean on Labtech LT-4500?
A 'Lamp Overflow' error on the Labtech Card Reader indicates a hardware problem, specifically an electronic defect.
What causes Lamp Low error on Labtech LT-4500 Card Reader?
A 'Lamp Low' error on the Labtech Card Reader indicates a hardware problem, such as an electronic defect or a broken fiber.
What does Channel Low mean on Labtech Card Reader?
A 'Channel Low' error on the Labtech Card Reader indicates a hardware problem, such as an electronic defect or a broken fiber.
What causes MTP Init Error on Labtech LT-4500?
The 'MTP Init Error' on the Labtech Card Reader is due to a hardware problem, such as an electronic defect, a broken belt, or the MTP transport being mechanically blocked.
What does Filter Init Error mean on Labtech LT-4500?
The 'Filter Init Error' on the Labtech Card Reader is due to a hardware problem, such as an electronic defect or the filter wheel transport being mechanically blocked.
Brand | Labtech |
---|---|
Model | LT-4500 |
Category | Card Reader |
Language | English |
Essential safety precautions for operating the instrument and avoiding risks.
Describes the instrument's purpose, target users, and application scope.
Procedure for inspecting delivered packaging and unpacking the instrument.
Covers switching on the instrument and installing/qualifying the LT-com software.
Details the interface for setting up measurement workflows and parameters.
Provides examples for defining endpoint, multilabel, and kinetic measurements.
Provides detailed technical specifications for the LT-4500 absorbance reader.
Detailed guide on creating a quantitative ELISA method in LT-com.
Lists common error messages, their descriptions, and recommended troubleshooting actions.