Using XPort™Installer
You can configure the display panel for your application. Click the Config button (top, left
corner) and select Set Config. The Configuration Panel displays.
Use the text fields, list boxes and color panels to configure the display panel for your
application.
You can query the states of the pins manually by selecting Manual. This mode requires you
to click the Update States button on the display panel each time you want an update,
whether the pins are configured as Inputs or Outputs. When the configurable pins are set to
Inputs, the query can be automatic by selecting Automat and entering the amount of time.
Note the time is in multiples of 100ms. Click the Default button to reset all options to the
original states. Click Ok to close the configuration panel and return to the control page.
The evaluation board has LEDs that can be tied directly to the configurable pins. See
(Configuration Switch Bank) for more information. In order to use the LEDs with the applet,
you must set the switches on the switch bank properly. For CPI LED, SW1-2 must be in the
ON position. For CP2 LED, SW1-3 must be in the ON position. For CP3 LED, SW1-5 must
be in the ON position.
In the above example, the configurable pins have been configured as Outputs. When you
return to the control page, you can click on the On LED, then click the Update states button
and the corresponding LED on the evaluation board will turn On. For example, if you click
the On LED for CP1, then click the Update states button, the CP1 LED on the evaluation
board will turn On.
You can save the display panel configuration. Click the Config button (top, left corner) and
select Save Config. The next time the control page is opened, the saved configuration is
loaded. Use the Load Config option to reload the saved configuration.
6.10.9 Ports
The Ports section is used to configure the XPort™ serial port parameters.
When you click on the Ports field, a browse button appears. Click the button to display the
Port Collection Editor dialog box.
XPort™ User Manual and Development Kit 6-15

Table of Contents

Other manuals for Lantronix XPort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix XPort and is the answer not in the manual?

Lantronix XPort Specifications

General IconGeneral
Data Link ProtocolEthernet, Fast Ethernet
Connectivity TechnologyWired
Form FactorEmbedded
CategoryEmbedded Systems
InterfaceSerial
Serial Ports1
Operating Temperature0°C to 70°C

Related product manuals