Service Manual JET3
22 Rev. 1.0
5 Transport/Start up (Putting into service)
5.1 Transport, storage, shipping
In order to avoid damage during transport the following instructions must be observed.
The JET3up must only be transported in a standing position. It is packed in a cardboard box
with special polystyrene inserts for safe dispatch during delivery. Transport of the device
must only be made in this packing in order to avoid damage.
The printer should be only transported in an empty condition!
A special draining routine (“ServiceFunctions Hydraulic Special
Functions/ Tools Drain Routine“) is available for the draining of the
device.
You will find further information in the group Data input/Programming in
the chapter Draining routine!
Note! Storage temperatures below +5°C and above +50°C as well as storage at outside are
not admissible and can lead to damage!
Attention – Danger of explosion!
The device should be only operated outside of explosive areas! The
installation has to be carried out according to the installation instructions
of the manufacturer!
Attention – Danger of explosion!
Precautions regarding electrostatics have to be carried out!
Installation of the device
The device must be installed in a well ventilated room only and must be
kept away from any source of heat, flame or sparks, e.g. radiant heater,
etc..
Check device for damage! When determining a suitable place of setting up, the necessary
additional space requirement for the movement room of the operating and service personnel
must be taken into consideration. Solvents are processed in the device, adequate room
ventilation must be ensured!