31
Error and Warning List
Code - Nr
Error text
Reason
Solution
Remarks
2
2=Internal communication
error
Internal communication problem:
A CPU (RIP) has sent a message (identifier)
to a different CPU which is unknown.
Possibly, firmware, and software versions
are not compatible.
Carry out a software update
If software update is without
success, please contact
LEIBINGER
3
3=Internal communication
error.
Too much data.
Internal communication problem.
Internal message at the receiver was too
large (currently 1MB)
Carry out a software update
Check files on maximum size of 1
MB. fonts, graphics, or job
If no success, please contact
LEIBINGER
4
4=Internal communication
error
Internal communication problem.
Single data packet doesn't fit in the length
(= transmission errors)
Read the script and interface
protocol documentation!
If no success, please contact
LEIBINGER
5
5=Internal communication
error
Internal communication problem.
Block transfer error (= transmission errors)
Reboot again the system.
If no success, please contact
LEIBINGER
6
6=Internal communication
error.
Too much data.
Get to large amount of data.
Reboot again the system.
If no success, please contact
LEIBINGER
7
7=Internal communication
error
Internal communication problem:
A CPU (RIP) has sent a message (identifier)
to a different CPU which is unknown.
Reboot again the system.
Carry out a software update.
Change the controller board.
See the service document
"Exchange the Controller board
JET3up"
If no success, please contact
LEIBINGER