1303=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The maximum fall time of 16.4 seconds was
exceeded
i.e. the ball has passed the upper sensor,
but it has not arrived at the lower sensor.
1 Ink is extremely thick
2. Lower sensor defective (no signal
delivers)
3. Ball is stuck on the way down
Take out the viscometer and flush
it several times with solvent.
If no success exchange the
viscometer.
1304=Faulty visco-
measurement.
Please check visco pump
and viscometer.
The minimum event time of 500ms has been
exceeded.
1 Lower sensor defective (provides
continuous signal)
2. Air in the tube?
1305=Attention, ink too
thick!
Fall time of the ink is 2 seconds higher than
the nominal fall time (= ink to thick)
Note!
This error message is issued only once after
switching on.
After confirmation of the error this is not
repeated.