2.Rerunthetest.
3.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
406-903-000:IANet:InterruptsTestFailed
AfailurewasdetectedduringtheInterrupttest.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Checkcomponentfirmwarelevelandupgradeifnecessary.Theinstalledfirmwarelevelcanbe
foundintheDSADiagnosticEventLogwithintheFirmware/VPDsectionforthiscomponent.
2.Rerunthetest.
3.CheckinterruptassignmentsinthePCIHardwaresectionoftheDSADiagnosticLog.Ifthe
ethernetdeviceissharinginterrupts,ifpossiblemodifytheinterruptassignmentsusingF1
Setuptoassignauniqueinterrupttothedevice.
4.Rerunthetest.
5.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
406-904-000:IANet:LoopbackTestFailed
AfailurewasdetectedduringtheLoopbacktest.
Recoverable
No
Severity
Error
Serviceable
AppendixC.DSAdiagnostictestresults1015