InstallinganadapterinaPCIriser-cardassembly
Thefollowingnotesdescribethetypesofadaptersthattheserversupportsandotherinformationthat
youmustconsiderwhenyouinstallanadapter.
•Locatethedocumentationthatcomeswiththeadapterandfollowthoseinstructionsinadditionto
theinstructionsinthissection.
•TheserverprovidestwointernalSASconnectorsandtwoSAS/SATARAIDriser-cardslotsonthesystem
board.See“System-boardoptional-deviceconnectors”onpage32forthelocationoftheinternal
SAS/SATARAIDconnectorandriser-cardslots.YoucanreplacetheLenovoServeRAIDSAS/SATA
adapterwithanoptionalLenovoServeRAIDSAS/SATAadapterintheslot.Forconfigurationinformation,
seetheServeRAIDdocumentationathttp://www.lenovo.com/support.
•Donotsetthemaximumdigitalvideoadapterresolutionabove1600x1200at75HzforanLCDmonitor.
Thisisthehighestresolutionthatissupportedforanyadd-onvideoadapterthatyouinstallintheserver.
•Theserverdoesnotsupportlegacy5VPCIadapters.
•WhenyouinstallanyPCIadapter,thepowercordsmustbedisconnectedfromthepowersourcebefore
youremovethePCIExpressriser-cardassemblyandthePCI-Xriser-cardassembly.Otherwise,the
activepowermanagementeventsignalwillbedisabledbythesystem-boardlogic,andtheWakeonLAN
featuremightnotwork.However,aftertheserverispowered-onlocally,theactivepowermanageractive
powermanagementeventsignalwillbeenabledbythesystem-boardlogic.
•TheserverprovidestwoPCIriser-cardslotsonthesystemboard.IfyouwanttoinstallaPCIExpressor
PCI-Xadapter,youmustorderthePCIriser-cardoption.
•IfyouareinstallingaServeRAID-M5110orServeRAID-M5120adapter,itcanonlybeinstalledinPCI
slot1,2,4,or5.
Thefollowingtableshowsthelocationsoftheadapterexpansionslotsfromtherearoftheserver.
Table10.Themaximumadapterdimensionsupportedineachslot(rearview)
PCIriser-cardassembly1PCIriser-cardassembly2
1
Fullheight,uptofulllength
4
Fullheight,uptofulllength
2
Fullheight,halflength
5
Fullheight,uptofulllength
3
Fullheight,halflength
6
Fullheight,halflength
Toinstallanadapter,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”
onpage34
.
Step2.Turnofftheserverandperipheraldevicesanddisconnectthepowercordsandallexternalcables.
Step3.Removetheservercover(see“Removingthecover”onpage37).
Step4.Determinewhichexpansionslotyouwillusefortheadapter.
Step5.IfyouareinstallinganadapterinPCIexpansionslot1,2,or3,removePCIriser-cardassembly1;if
youareinstallinganadapterinPCIexpansionslot4,5,or6,removePCIriser-cardassembly2.
See“RemovingaPCIriser-cardassembly”onpage221.
Step6.Rotatethebracketoutoftheway.
Step7.Slidetheexpansion-slotcoveroutofthePCIriser-cardassemblyexpansionslot.
50LenovoSystemx3650M4HDInstallationandServiceGuide