Step6.Installtheheatsinkontothemicroprocessor.See“Replacingamicroprocessorandheatsink”on
page287
.
Installingthe8x2.5-inchhot-swapHDDassemblykitwithexpander
Usethisinformationtoaddeight2.5-inchhard-disk-drivebaysintheserver.
YoucaninstallanLenovoSystemx3650M4HDPlusEight2.5-inchHot-SwapHDDAssemblyKit
withExpandertoaddeightadditional2.5-inchhot-swaphard-disk-drivebaysintheserver.See
http://www.lenovo.com/serverproven/foralistofsupportedoptionaldevices.Toordera8x2.5-inch
hot-swapHDDassemblykitwithexpander,contactyourLenovosalesrepresentativeorLenovoreseller.
The8x2.5-inchhot-swapHDDassemblykitwithexpandercontainsthefollowingcomponents:
•Oneexpander
•Onebackplaneconnectioncable
•Twoscrews
•Onepowercable
•Oneconfigurationcable
•Eight2.5-inchHDDfillers
Note:TheoptionincludingstructuralpartsandTier1parts.
Toinstallthe8x2.5-inchhot-swapHDDassemblykitwithexpander,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”
onpage34.
Step2.Removethecover(see“Removingthecover”onpage37).
Step3.Touchthestatic-protectivepackagethatcontainstheexpandertoanyunpaintedsurfaceonthe
outsideoftheserver;then,grasptheexpanderandremoveitfromthepackage.
Step4.Installtheexpanderinthefarthestslotfromthepowersupplies.
80LenovoSystemx3650M4HDInstallationandServiceGuide