TheEthernetlinkstatusLEDislitwhentheEthernetcontrollerreceivesalinkpulsefromthehub.
IftheLEDisoff,theremightbeadefectiveconnectororcableoraproblemwiththehub.
TheEthernettransmit/receiveactivityLEDislitwhentheEthernetcontrollersendsorreceives
dataovertheEthernetnetwork.IftheEthernettransmit/receiveactivityisoff,makesurethatthe
hubandnetworkareoperatingandthatthecorrectdevicedriversareinstalled.
Step5.ChecktheLANactivityLEDontherearoftheserver.TheLANactivityLEDislitwhendataisactive
ontheEthernetnetwork.IftheLANactivityLEDisoff,makesurethatthehubandnetworkare
operatingandthatthecorrectdevicedriversareinstalled.
Step6.Checkforoperating-system-specificcausesoftheproblem.
Step7.Makesurethatthedevicedriversontheclientandserverareusingthesameprotocol.
IftheEthernetcontrollerstillcannotconnecttothenetworkbutthehardwareappearstobeworking,the
networkadministratormustinvestigateotherpossiblecausesoftheerror.
Solvingundeterminedproblems
IfDynamicSystemAnalysis(DSA)didnotdiagnosethefailureoriftheserverisinoperative,usethe
informationinthissection.
Ifyoususpectthatasoftwareproblemiscausingfailures(continuousorintermittent),see“Software
problems”onpage157.
CorrupteddatainCMOSmemoryorcorruptedUEFIfirmwarecancauseundeterminedproblems.Toreset
theCMOSdata,usetheCMOSclearjumper(JP1)tocleartheCMOSmemoryandoverridethepower-on
password;seeTable3“Systemboardjumpers”onpage30formoreinformation.Ifyoususpectthatthe
UEFIfirmwareiscorrupted,see“Recoveringtheserverfirmware(UEFIupdatefailure)”onpage162
.
Ifthepowersuppliesareworkingcorrectly,completethefollowingsteps:
Step1.Turnofftheserver.
Step2.Makesurethattheserveriscabledcorrectly.
Step3.Removeordisconnectthefollowingdevices,oneatatime,untilyoufindthefailure.Turnonthe
serverandreconfigureiteachtime.
Anyexternaldevices.
Surge-suppressordevice(ontheserver).
Printer,mouse,andnon-Lenovodevices.
Eachadapter.
Harddiskdrives.
Memorymodules.Theminimumconfigurationrequirementis2GBDIMMinslot1.
Step4.Turnontheserver.
Iftheproblemissolvedwhenyouremoveanadapterfromtheserverbuttheproblemrecurswhenyou
reinstallthesameadapter,suspecttheadapter;iftheproblemrecurswhenyoureplacetheadapterwith
adifferentone,suspecttherisercard.
Ifyoususpectanetworkingproblemandtheserverpassesallthesystemtests,suspectanetworkcabling
problemthatisexternaltotheserver.
Problemdeterminationtips
Becauseofthevarietyofhardwareandsoftwarecombinationsthatcanencounter,usethefollowing
informationtoassistyouinproblemdetermination.
160LenovoSystemx3650M4HDInstallationandServiceGuide