Serviceable
No
Automaticallynotifysupport
No
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
202-801-000:MemStrT estAborted
Internalprogramerror.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Turnoffandrestartthesystem.
2.MakesurethattheDSADiagnosticcodeisatthelatestlevel.
3.Runthetestagain.
4.Ifthesystemhasstoppedresponding,turnoffandrestartthesystem.
5.Checkthesystemfirmwarelevelandupgradeifnecessary.
6.RunthememorydiagnostictoidentifythespecificfailingDIMM.
7.Ifthefailureremains,referto"Troubleshootingbysymptom"inthesystem"Installationand
ServiceGuide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
202-802-000:MemStrT estAborted
Memorysizeisinsufficienttorunthetest.Atleast1GBisrequired.
Recoverable
No
Severity
Warning
AppendixC.DSAdiagnostictestresults1099