a.Insertthedriveintothedrivebaywiththelabelsideofthedrivefacingtherightsideofthe
server.
1.8-inch
hot-swap
hard disk drive
Filler
Figure136.1.8-inchhot-swapsolidstatedrivesinstallation
b.Pushthedrivetrayintothedrivebayandrotatethedrivetrayhandletotheclosedposition
andensurethatthelatchisinthelockedposition.
c.Reinstallthefillerpanel.
Step6.ChecktheharddiskdrivestatusLEDtoverifythattheharddiskdriveisoperatingcorrectly.If
theyellowharddiskdrivestatusLEDofadriveislitcontinuously,thatdriveisfaultyandmustbe
replaced.IfthegreenharddiskdriveactivityLEDisflashing,thedriveisbeingaccessed.
Note:IftheserverisconfiguredforRAIDoperationusingaServeRAIDadapter,youmighthave
toreconfigureyourdiskarraysafteryouinstallharddiskdrives.SeetheServeRAIDadapter
documentationforadditionalinformationaboutRAIDoperationandcompleteinstructionsfor
usingtheServeRAIDadapter.
Step7.Ifyouareinstallingadditionalhot-swapharddiskdrives,dosonow.
Step8.Turnontheperipheraldevicesandtheserver.
DriveIDs
ThedriveIDthatisassignedtoeachdriveisprintedonthefrontorrearoftheserver.Thefollowing
illustrationsshowthelocationsoftheIDsofthedrives.TheIDnumbersandthedrivebaynumbersare
thesame.
2.5-inchhot-swapharddiskdriveIDs
Thehot-swap-driveIDthatisassignedtoeachdriveisprintedonthefrontorrearoftheserver.
ThefollowingillustrationshowsthelocationoftheIDsoftheharddiskdrives.TheIDnumbersandthe
drivebaynumbersarethesame.
Chapter6.Removingandreplacingcomponents213