beconī±guredbetween0percentand100percent.At0percent,therebuildisdoneonlyifthesystemisnot
doinganythingelse.At100percent,therebuildhasahigherprioritythananyothersystemactivity.
Toconī±guretherebuildrateusingtheLSISoftwareRAIDConī±gurationUtilityprogram,dothefollowing:
Note:Usingarebuildrateof0or100percentisnotrecommended.Thedefaultvalueis30percent.
1.StarttheLSISoftwareRAIDConī±gurationUtilityprogram.SeeāStartingtheLSISoftwareRAID
Conī±gurationUtilityprogramāonpage76
.
2.Onthemaininterfaceoftheprogram,selectObjectsāAdapterāRebuildRate.
Note:UseupanddownarrowkeystonavigatebetweenitemsandpressEntertoselectanoption.
3.Settherebuildratebytypingadesiredvaluefromthekeyboarddirectly.
Runningaconsistencycheck
ThistopicprovidesinstructionsonhowtorunaconsistencycheckforvirtualdrivesusingtheLSISoftware
RAIDConī±gurationUtilityprogram.
Aconsistencycheckisanoperationthatveriī±esthatallstripesonavirtualdrivewitharedundantRAID
levelareconsistent.Theconsistencycheckoperationveriī±escorrectnessofthedataonvirtualdrivesthat
useRAID1,5,and10(RAID0doesnotprovidedataredundancy).Forexample,inasystemwithparity,
checkingconsistencymeanscomputingthedataononedriveandcomparingtheresultstothecontentsof
theparitydrive.
Youshouldrunaconsistencycheckonfault-tolerantvirtualdrivesperiodically.Itisrecommendedthatyou
runaconsistencycheckatleastonceamonth.Youmustrunaconsistencycheckifyoususpectthatthe
virtualdrivedatamightbecorrupted.Besuretobackupthedatabeforerunningaconsistencycheckifyou
suspectthedatamightbecorrupted.
TorunaconsistencycheckusingtheLSISoftwareRAIDConī±gurationUtilityprogram,dothefollowing:
1.StarttheLSISoftwareRAIDConī±gurationUtilityprogram.SeeāStartingtheLSISoftwareRAID
Conī±gurationUtilityprogramāonpage76
.
2.Onthemaininterfaceoftheprogram,selectCheckConsistencyandfollowtheinstructionsonthe
screen.
Theconsistencycheckrateistherateatwhichconsistencycheckoperationsarerunonasystem.The
consistencycheckratecanbeconī±guredbetween0percentand100percent.At0percent,theconsistency
checkisdoneonlyifthesystemisnotdoinganythingelse.At100percent,theconsistencycheckhasa
higherprioritythananyothersystemactivity.
Toconī±guretheconsistencycheckrateusingtheLSISoftwareRAIDConī±gurationUtilityprogram,do
thefollowing:
Note:Usingaconsistencycheckrateof0or100percentisnotrecommended.Thedefaultvalueis30
percent.
1.StarttheLSISoftwareRAIDConī±gurationUtilityprogram.SeeāStartingtheLSISoftwareRAID
Conī±gurationUtilityprogramāonpage76.
2.Onthemaininterfaceoftheprogram,selectObjectsāAdapterāChkConstRate.
Note:UseupanddownarrowkeystonavigatebetweenitemsandpressEntertoselectanoption.
3.Settheconsistencycheckratebytypingadesiredvaluefromthekeyboarddirectly.
80ThinkServerTS430UserGuide