12.Slidetheharddiskdrivecageintothechassisfromthefrontuntilitsnapsintoposition.
Note:Thefollowingillustrationshowsthe3.5-inchharddiskdrivecage.Forthe2.5-inchharddisk
drivecage,theinstallationprocedureisthesame.
Figure75.Installingtheharddiskdrivecage
13.Reinstallallthehot-swapharddiskdrivesanddummytrays(ifany)intheharddiskdrivecage.See
“Installingorreplacingahot-swapharddiskdrive”onpage101.
14.Refertoyournotetoreconnectthecablestothebackplane.
15.Reinstallthefrontsystemfan1.See“Replacingthefrontsystemfan1”onpage128.
16.Reinstallthefrontbezel.See“Removingandreinstallingthefrontbezel”onpage67.
17.Ifyouareinstructedtoreturntheoldhot-swapharddiskdrivebackplane,followallpackaging
instructionsanduseanypackagingmaterialsthataresuppliedtoyouforshipping.
Whattodonext:
Toworkwithanotherpieceofhardware,gototheappropriatesection.
Tocompletethereplacement,goto“Completingthepartsreplacement”onpage141
.
Replacingthenon-hot-swappowersupplyassembly
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”
onpageiii
and“Guidelines”onpage63.
Thistopicprovidesinstructionsonhowtoreplacethenon-hot-swappowersupplyassembly.Thistopic
appliesonlytoservermodelsthatcomewithanon-hot-swappowersupplyassembly.