Running device failure diagnostics
Running diagnostics can help you determine why access to a specific device becomes intermittent or why
the device becomes unavailable in your storage system.
Step 1. At the storage system prompt, switch to the LOADER prompt: halt
Step 2. Enter the following command at the LOADER prompt: boot_diags
Note: You must run this command from the LOADER prompt for system-level diagnostics to
function properly. The bboooott__ddiiaaggss command starts special drivers designed specifically for
system-level diagnostics.
Step 3. Run diagnostics on the device causing problems by entering the following command: sldiag device
run [-dev devtype|mb|slotslotnum] [-name device]
-dev devtype specifies the type of device to be tested.
ata is an Advanced Technology Attachment device.
bootmedia is the system booting device.
cna is a Converged Network Adapter not connected to a network or storage device.
env is motherboard environmentals.
fcache is the Flash Cache adapter, also known as the Performance Acceleration Module 2.
fcal is a Fibre Channel-Arbitrated Loop device not connected to a storage device or Fibre
Channel network.
fcvi is the Fiber Channel Virtual Interface not connected to a Fibre Channel network.
interconnect or nvram-ib is the high-availability interface.
mem is system memory.
nic is a Network Interface Card not connected to a network.
nvram is nonvolatile RAM.
nvmem is a hybrid of NVRAM and system memory.
sas is a Serial Attached SCSI device not connected to a disk shelf.
serviceproc is the Service Processor.
storage is an ATA, FC-AL, or SAS interface that has an attached disk shelf.
toe is a TCP Offload Engine, a type of NIC.
mb specifies that all the motherboard devices are to be tested.
slot slotnum specifies that a device in a specific slot number is to be tested.
-name device specifies a given device class and type.
Step 4. View the status of the test by entering the following command: sldiag device status
Your storage system provides the following output while the tests are still running:
There are still test(s) being processed.
After all the tests are complete, the following response appears by default:
*> <SLDIAG:_ALL_TESTS_COMPLETED>
Step 5. Identify any hardware problems by entering the following command: sldiag device status [-dev
devtype|mb|slotslotnum] [-name device] -long -state failed
Example
The following example shows how the full status of failures resulting from testing the FC-AL
adapter are displayed:
Chapter 7. System level diagnostics 121

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenovo ThinkSystem DM5000 series and is the answer not in the manual?

Lenovo ThinkSystem DM5000 series Specifications

General IconGeneral
BrandLenovo
ModelThinkSystem DM5000 series
CategoryStorage
LanguageEnglish

Related product manuals