Error Count: 2 Run Time: 70 secs
>>>>> ERROR, please ensure the port has a shelf or plug.
END DATE: Sat Jan 3 23:12:07 GMT 2009
LOOP: 1/1
TEST END --------------------------------------------
If the system-level diagnostics tests...
Then...
Were completed without any failures There are no hardware problems and your
storage system returns to the prompt.
1. Clear the status logs by entering the
following command: sldiag device
clearstatus
2. Verify that the log is cleared by entering
the following command: sldiag device
status
The following default response is
displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode by entering the
following command: halt
4. Enter the following command at the
Loader prompt to boot the storage
system: boot_ontap
You have completed system-level diagnostics.
Resulted in some test failures Determine the cause of the problem.
1. Exit Maintenance mode by entering the
following command: halt
2. Perform a clean shutdown and disconnect
the power supplies.
3. Verify that you have observed all the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4. Reconnect the power supplies and power
on the storage system.
5. Repeat Steps 1 through 5 of Running
system panic diagnostics.
After you finish
If the failures persist after repeating the steps, you need to replace the hardware.
Running slow system response diagnostics
Running diagnostics can help you identify the causes of slow system response times.