If the system-level diagnostics tests...
Then...
2. Verify that the log is cleared by entering
the following command: sldiag device
status [-dev devtype|mb|slotslotnum] The
following default response is displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode by entering the
following command: halt
4. Enter the following command at the
Loader prompt to boot the storage
system: boot_ontap
You have completed system-level diagnostics.
After you finish
If the failures persist after repeating the steps, you need to replace the hardware.