Function block library
7-38
SHB9300CRV EN 2.0
Example for an output value
AOUT1-IN = 50%, AOUT1-GAIN = 100%, AOUT1-OFFSET = 10%
Output terminal 62 = ((50% * 100% = 50%) + 10% = 60%) = 6 V
AOUT-GAIN
AOUT-IN
OUT
AOUT-OFFSET
Fig. 7-26 Offset and gain of the analog output