Function block library
7-87
SHB9300CRV EN 2.0
CONV6
CONV6
CONV6-OUT
CONV6-IN
C 1173
C 1172
C 1170
C 1171
Fig. 7-62 Function block CONV6
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV6-IN a C1173 dec [%] C1172 1 1000
CONV6-OUT phd - - - - - Limited to ±29999 rpm
This function block is used to convert analog signals into speed signals.
The conversion is done according to the formula:
CONV6-OUT
CONV6-IN
ô
15000rpm
100%
ô
C1170
C1171
Show/Hide Bookmarks