Configuration
7-295
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0868
1
2
3
4
5
6
7
8
9
10
11
DIS: OUT1.W1
DIS: OUT1.W2
DIS: OUT1.W3
DIS: OUT2.W1
DIS: OUT2.W2
DIS: OUT2.W3
DIS: OUT2.W4
DIS: OUT3.W1
DIS: OUT3.W2
DIS: OUT3.W3
DIS: OUT3.W4
-199.99 {0.01%} 199.99
C0869
1
2
3
DIS: OUT1.D1
DIS: OUT2.D1
DIS: OUT3.D1
0 -2147483648/ {1} 2147483647 Display: CAN OUT1/OUT2.Dx (phase)
CCTRL
C0430
4
TP4 delay 0.218
0.000 {0.001ms} 2.000
TP1 delay
C1340
1
2
CFG: NRED
CFG: MRED
1000 FIXED 0%
@
Selection list 1 1: Gain for speed setpoint precontrol
2: Gain for torque setpoint precontrol
C1341 DIS: C1340 -199.99 {0.01%} 199.99 Display of C1340
C1342
1
2
3
4
5
CFG: RESET
CFG: TPIN
CFG: N2-SET
CFG: TPIN/E4
CFG: SUB-Y-END
1000 FIXED 0
@
Selection list 2 1: HIGH: Set phase = act. phase
-> CCTRL-POUT = 0
2: External mark to set the position
3: HIGH = Input -NSET2 active
4: Selection:Input TPIN
G
term. X5/E4 (TOUCH-PROBE
initiator)
5: Acceptance for profile end
C1343 DIS: C1342 Display of C1342
C1344
1
2
CFG: Y-END
CFG: TP-POS
1000 FIXED0 INC
@
Selection list 3 Upper range value of the profile (only required for touch
probe)
C1345 DIS: C1344 Display of C1344
C1346
1
2
CFG: IN
CFG: NSET2
1000 FIXEDPHI-0 INC
@
Selection list 4 1:Input for main setpoint
2:Input for alternative setpoint (2nd setpoint)
C1347 DIS: C1346 Display of C1346
C1348
1
2
100
1
1 {1} 32767
CDATA
C1300 8 1/ ... /8 Display of number of profiles used
C1301
1
..
8
0 ... 2048 Display of points in profile 1/ .. /8.
Depends on the number of profiles selected.
C1303
1
2
1 1 {1} 65535 Gearbox factor
1 Master value numerator
2 Master value denominator
C1304 1.0000 0.0001 {0.0001 units/rev.} 214000.0000 Output feed constant - master value
C1305
1
2
1 1 {1} 65535 Gearbox factor
1: Act. value numerator
2: Act. value denominator
C1306 1.0000 0.0001 {0.0001 units/rev.} 214000.0000 Output feed constant - act. value
C1309 10 1{1inc.}18
ô
10
8
Window for zero crossing of the master va-
lue
C1311 0.0 0{1}7Start profile for cyclic cam profile processing
0 = 1. profile, 1 = 2. profile, ...
Input CDATA-CYCLE must be on ’H. Is internally limited
to a profile.