Configuration
7-296
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C1312 0.0 0{1}7Reach of cam profile processing
Another x profiles (starting with C1311) will be proces-
sed
C1314 0 0CWrotation
1 CCWrotation
Direction of rotation - master value
C1315
1
..
8
DIS:
Clock pulse length of the master value
Profile 1 .. 8
C1316
1
..
8
DIS:
Y upper range value of profile (1...8)
C1320
2
3
CFG: XFACT
CFG: SEL
1006
1000
FIXED0 %
@
Selection list 1
2: Factor (stretch./compr.)
+100% = no compression/stretching,
> 100% = compression,
< 100% = stretching
3: Profile selection, 0 = profile 0 (1. profile)
C1321
2
3
DIS: XFACT
DIS: SEL
C1322
1
2
3
4
5
6
7
8
CFG: CYCLE
CFG: RESET
CFG: REL-SEL
CFG: XRESET
CFG: X-TP
CFG: HOLD
CFG: LOAD
CFG: X-TP/E5
1000 FIXED 0
@
Selection list 2 Auto. cam profile processing
1. HIGH = Profiles (C1311 and C1312) are cyclically
processed.
2. HIGH, if CDATA-CYCLE = LOW, the input CDATA-SEL
is immediately evaluated; if CDATA-CYCLE = HIGH,
the profile from C1311 will be processed.
3. HIGH, feed function active
4. HIGH, sets master value integrator to 0
5. HIGH, sets master value integrator to TP-POS, if
input X-TP/E5 = LOW
6. HIGH, inhibits cam profile processing, input has
priority
7. Transition LOW
@
H: activates profiles loaded later
or new
8. Selection of TP initiator:
LOW= Initiator at X-TP
HIGH = Connect initiator to term. X5/E5
C1323 DIS:C1323 Display of C1323
C1324
2
3
4
CFG: XIN
CFG: XOFFS
CFG: TP-POS
1000
1000
19616
@
Selection list 3
FIXED0 INC
FIXED0 INC
FCODE 1476/16
2: Input for the master value position if C1332 = 1
3: Input for offset in X direction (only if C1332 = 0)
4: TP position of the master value
C1325 DIS: C1324 Display of C1324
C1326 CFG: DFIN 1000 FIXEDPHI-0
@
Selection list 3 Input for digital frequency if C1332 = 0
C1327 DIS: C1326 Display of C1326
C1332 Selection of master
value
0 0{1}1Selection of master value
0 = CDATA-DFIN (dig. frequency, internal master)
1 = CDATA-XIN (external selection of X position)
C1333 DIS: actual
X position
Display of the actual X position
C1334 DIS: actual
Y position
Display of the actual Y position
CERR
C1380
1
2
ERR ?
WA RN
10 10 {1 inc} 1800000000
1: Hysteresis fault signal output-ERR
2: Hysteresis fault signal output-WARN
C1384 CFG: WFAC 1000
@
Selection list 1
FIXED0
Reduction factor for CERR1-WARN:
+100% = no reduction
< 100% = reduction
> 100% = increase
C1385 DIS: C1384 Display of C1384