Configuration
7-297
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C1386 CFG: DISABLE 1000
@
Selection list 1
FIXED0%
HIGH sets CERR1-WARN and CERR1-EER = 0
C1387 DIS: C1386 Display of C1386
C1388
1
2
CFG: PHI-IN
CFG: LIM
1000
@
Selection list 4
FIXED0INC
1: Input
2: Threshold, absolute value is generated from input
value
C1389 DIS: C1388 Display of C1388
CLUTCH
C1410 Clutch mode 0 0{1}30 directly engaged
1 to open position
2 to target position
3 latch at set position
C1411 max. velocity 200.00 1 {0.0000 rpm} 16000.0000
C1412
1
2
3
Open time ramp
Ramp profile genera-
tor
Time delay overload
1.0 0.010 {0.010 s} 130.000
C1413 Catch hysteresis 163 5{1inc}18
ô
10
8
C1414
1
2
CFG: MLIM
CFG: MACT
1000 FIXED 0%
@
Selection list 1 1. 1: Threshold for monitoring overload”
2. 2: Act. value for monitoring overload”
C1415 DIS: C1414 Display of C1414
C1416
1
2
CFG: CLOSE
CFG: OL-DET
1000 FIXED 0
@
Selection list 2 1. HIGH = engage clutch
LOW = disengage clutch
2. HIGH = activate overload monitoring
C1417 DIS: C1416 Display of C1416
C1418
1
2
CFG: PHI-SET
CFG: PHI-ACT
1000 FIXED0 INC
@
Selection list 3
1. Set drive position
2. Act. drive position
C1419 DIS: C1418 Display of C1418
CMP
C0680 Function 6 1{1}6Function comparator CMP1, compares inputs IN1 and
IN2
1IN1=IN2
2IN1>IN2
3IN1<IN2
4 |IN1| = |IN2|
5 |IN1| > |IN2|
6 |IN1| < |IN2|
C0681 Hysteresis 1.00 0.00 {0.01 %} 100.00 % Hysteresis of CMP1
C0682 Window 1.00 0.00 {0.01 %} 100.00 % Window of CMP1
[C0683]
1
2
CFG: IN
CFG: IN
5001
19500
@
Selection list 1
MCTRL-NACT
FCODE-17
Configuration analog inputs of CMP1
C0684 DIS: C0683 -199.99 {0.01 %} 199.99 Display of C0683
C0685 Function 00001 1{1}6CMP2 Comparison function
1 IN1 = IN2
2 IN1 > IN2
3 IN1 < IN2
4 |IN1| = |IN2|
5 |IN1| > |IN2|
6 |IN1| < |IN2|
C0686 Hysteresis 1.00 0.00 {0.01 %} 100.00 CMP2 Hysteresis
C0687 Window 1.00 0.00 {0.01 %} 100.00 CMP2 window
[C0688]
1
2
CFG: IN
CFG: IN
1000 FIXED 0%
@
Selection list 1 Configuration analog inputs of CMP2
C0689 DIS: C0688 -199.99 {0.01 %} 199.99 Display of C0688
Show/Hide Bookmarks