Configuration
7-300
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0042 DIS: QSP 0{1}1Quick stop status
0QSPinactive
1QSPactive
C0135 Control word 0 0 {1} 65535 Control word
Controller control word for LECOM-A/B/LI or operating
module.
C0136 DIS: C0135 Display of C0135
C0142 Start options 1 0{1}1Start conditions are executed:
l
after mains connection
l
after message (t > 0.5s)
l
after trip
0Startlock
1 Autostart
[C0870]
1
2
CFG: CINH1
CFG: CINH2
1000 FIXED0
@
Selection list 2 Digital inputs (inhibit controller)
[C0871] CFG: TRIP-SET 54 DIGIN 4
@
Selection list 2 Digital input (TRIP set) of DCTRL
[C0876] CFG: TRIP-RES 55 DIGIN 5
@
Selection list 2 Digital input (TRIP reset) of DCTRL
C0878
1
2
3
4
DIS: C0870/1
DIS: C0870/2
DIS: C0871
DIS: C0876
Display of
C0870 /1 /2
C0871
C0876
C0879
1
2
3
Reset C135
Reset AIF
Reset CAN
0 0{1}1Reset control words
0 no reset
1 reset
DFIN
C0425 DFIN const 3 0{1}6DF input; increment of the digital frequency input
0 256 inc/rev
1 512 inc/rev
2 1024 inc/rev
3 2048 inc/rev
4 4096 inc/rev
5 8192 inc/rev
6 16384 inc/rev
C0426 DIS: OUT -32767 {1 rpm} 32767 Output signal of DFIN
C0427 DFIN function 0 0{1}2Type of the digital frequency signal
0 2 phases
1 A pulse / B dir
2PulseAorB
C0429 TP5 delay 0 -32767 {1 inc} 32767 TP5 delay
C0430
1
2
3
4
TP1 delay
TP2 delay
TP3 delay
TP4 delay
0.218 0.000 {0.001ms} 2.000 TPx delay
DFOUT
C0030 DFOUT const 3 0{1inc/rev}6Constant for the digital frequency output in
increments per revolution
0 256
1 512
2 1024
3 2048
4 4096
5 8192
6 16384
C0430
1
2
3
4
TP1 delay
TP2 delay
TP3 delay
TP4 delay
0.218
0.218
0.218
0.218
0.000 {0.001ms} 2.000 TPx delay