Configuration
7-321
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
TRANS
C0710 Function 0 0{1}2Transition evaluation TRANS1
0 Rising trans
1 Falling trans
2 Both trans
C0711 Pulse T 0.001 0.001 {0.001 s} 60.000 Pulse time of TRANS1
[C0713] CFG: IN 1000 FIXED 0
@
Selection list 2 Digital input of TRANS1
C0714 DIS: C0713 Display of C0713
C0715 Function 0 0{1}2Transition evaluation TRANS2
0 Rising trans
1 Falling trans
2 Both trans
C0716 Pulse T 0.001 0.001 {0.001 s} 60.000 Pulse time of TRANS2
[C0718] CFG: IN 1000 FIXED 0
@
Selection list 2 Digital input of TRANS2
C0719 DIS: C0718 Display of C0718
C1140 Function 0 0{1}2Transition evaluation TRANS3
0 Rising trans
1 Falling trans
2 Both trans
C1141 Pulse T 0.001 0.001 {0.001 s} 60.000 Pulse time of TRANS3
[C1143] CFG: IN 1000 FIXED 0
@
Selection list 2 Digital input of TRANS3
C1144 DIS: C1143 Display of C1143
C1145 Function 0 0{1}20 rising transition
1 falling transition
2 both transitions
C1146 pulse time 0.001 0.001 {0.001 s} 60.000
[C1148] CFG: IN 1000 FIXED 0
@
Selection list 2 Digital input of TRANS4
C1149 DIS: C1148 Display of C1148
VMAS
C1460 Selection setpoint
source
0 0{1}10 Analog setpoint AIN
1 Phase difference setpoint DFIN
C1461
1
2
CWspeed
CCW speed
300 -16000.0000 {0.0001 rpm} 16000.0000
C1462
1
2
Acceleration time
Deceleration time
1.000 0.010 {0.001 s} 999.990
C1463
1
2
Window ramp func-
tion generator
Hysteresis ramp
function generator
100 0 {1 rpm} 16000
C1466
1
2
VMAS1-AIN
VMAS1-RED-VAL
1000 FIXED 0%
@
Selection list 1 1. Analog setpoint
2. Alternative analog setpoint, target for speed
reduction
C1467 DIS: C1466 Display of C1466
C1468
1
2
3
4
5
VMAS1-EN-AIN
VMAS1-EN-RED
VMAS1-EN-RFG
VMAS1-CW
VMAS1-CCW
1000 FIXED 0
@
Selection list 2 1. HIGH = Activate the analog input VMAS1-AIN or
VMAS1-DFIN (depending on the selection under
C1460)
2. HIGH = Activate the analog input VMAS1-RED-VAL
3. HIGH = Active the ramp function generator LOW =
Input values are processed directly
4. Input CW rotation (determine speed in C1461/1)
5. Input CCW rotation (determine speed in C1461/2)
C1469 DIS: C1468 Display of C1468
C1472 VMAS1-DFIN 1000 FIXEDPHI-0
@
Selection list 4 Master speed input (digital frequency)
C1473 DIS: C1472 Display of C1472
Show/Hide Bookmarks