EasyManua.ls Logo

Lenze E82EV752K4C - Page 429

Lenze E82EV752K4C
588 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Code table
10
Function library
10.20
L
10.20-17
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0148*
s
Motor parameter
identification
0
0 Ready
Only when the motor is cold!
1. Inhibit controller , wait until drive is in
standstill
2. Enter the correct motor data under
C
0
0
8
7
C
0
0
8
8
C
0
0
8
9
C
0
0
9
0
C
0
0
9
1
^ 10.9-1
1 Start identification
V/f-rated frequency (C0015), slip
compensation (C0021) and motor stato r
inductivity (C0092) a re calculated and saved.
The motor stator resistance (C0084) = total
resistance of motor cable and motor is
measured and saved
C
0
0
8
7
,
C
0
0
8
8
,
C
0
0
8
9
,
C
0
0
9
0
,
C
0
0
9
1
(see motor nameplate).
3. C0148 = set 1 by
v
4. Enable controller
The identification
–starts,
c gets out
the motor makes a high-pitched tone,
but does not rotate!
takes approx. 30 s
is completed when
c is on again
5. Controller inhibit
C0150
*
Controller status
Bit Assignment
Scan of the controller status via
word 1 (parameter
c
h
a
n
n
e
l
0 Mapping of C0417/1
parameter channel. The most important
s
t
a
t
u
s
i
n
f
o
r
m
a
t
i
o
n
a
r
e
g
r
o
u
p
e
d
a
s
b
i
t
channel)
1
0
1
Pulse inhibit (DCTRL1-IMP)
Power outputs enabled
Power outputs inhibited
status information are grouped as bit
pattern.
Some bits can be freely assigned to
in
t
e
rn
a
l
d
i
g
i
t
a
l
s
i
g
n
a
l
s
2 Mapping of C0417/3
i
n
t
e
r
n
a
l
d
i
g
i
t
a
l
s
i
g
n
a
l
s
Configuration in C0417
3 Mapping of C0417/4
C
o
n
f
i
g
u
r
a
t
i
o
n
i
n
C
0
4
1
7
In keypad: display only (hexadecimal)
4 Mapping of C0417/5
y
p
p
y
y
5 Mapping of C0417/6
6
0
1
Output frequency = 0 (DCTRL1-NOUT=0)
false
true
7
0
1
Controller inhibit (DCTRL1-CINH)
Controller enabled
Controller inhibited
11|10|9|8 Controller status
0000 Controller initialization
0001 Mains voltage off (at external supply of the
control section ofthe drive controller)
0010 Switch-on inhibit
0011 Operation inhibited
0100 Flying-restart circuit active
0101 DC-injection brake active
0110 Operation enabled
0111 Message active
1000 Active error
12
0
1
Overheat warning (DCTRL1-OH-WARN)
No warning
ϑ
max
-5°C reached
13
0
1
DC-bus overvoltage (DCTRL1-OV)
No over voltage
Overvoltage
14 Mapping of C0417/15
15 Mapping of C0417/16
C0151
*
Controller status
word 2 (parameter
Bit Assignment
The bits can be freely assigned to
internal digital signals
w
o
r
d
2
p
a
r
a
m
e
t
e
r
channel)
0 ... 15 Mapping of C0418/1 ... C0418/16
i
n
t
e
r
n
a
l
d
i
g
i
t
a
l
s
i
g
n
a
l
s
Configuration in C0418
In keypad: display only (hexadecimal)
C0152
(A)
Service code Modifications only by Lenze Service!
Show/Hide Bookmarks

Table of Contents

Related product manuals