Code table
10
Function library
10.20
L
10.20-17
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0148*
s
Motor parameter
identification
0
0 Ready
Only when the motor is cold!
1. Inhibit controller , wait until drive is in
standstill
2. Enter the correct motor data under
^ 10.9-1
1 Start identification
• V/f-rated frequency (C0015), slip
compensation (C0021) and motor stato r
inductivity (C0092) a re calculated and saved.
• The motor stator resistance (C0084) = total
resistance of motor cable and motor is
measured and saved
,
,
,
,
(see motor nameplate).
3. C0148 = set 1 by
v
4. Enable controller
The identification
–starts,
c gets out
– the motor makes a high-pitched tone,
but does not rotate!
– takes approx. 30 s
– is completed when
c is on again
5. Controller inhibit
C0150
*
Controller status
Bit Assignment
• Scan of the controller status via
word 1 (parameter
0 Mapping of C0417/1
parameter channel. The most important
channel)
1
0
1
Pulse inhibit (DCTRL1-IMP)
Power outputs enabled
Power outputs inhibited
status information are grouped as bit
pattern.
• Some bits can be freely assigned to
in
rn
l
i
i
l
i
n
l
2 Mapping of C0417/3
• Configuration in C0417
3 Mapping of C0417/4
• In keypad: display only (hexadecimal)
4 Mapping of C0417/5
5 Mapping of C0417/6
6
0
1
Output frequency = 0 (DCTRL1-NOUT=0)
false
true
7
0
1
Controller inhibit (DCTRL1-CINH)
Controller enabled
Controller inhibited
11|10|9|8 Controller status
0000 Controller initialization
0001 Mains voltage off (at external supply of the
control section ofthe drive controller)
0010 Switch-on inhibit
0011 Operation inhibited
0100 Flying-restart circuit active
0101 DC-injection brake active
0110 Operation enabled
0111 Message active
1000 Active error
12
0
1
Overheat warning (DCTRL1-OH-WARN)
No warning
ϑ
max
-5°C reached
13
0
1
DC-bus overvoltage (DCTRL1-OV)
No over voltage
Overvoltage
14 Mapping of C0417/15
15 Mapping of C0417/16
C0151
*
Controller status
word 2 (parameter
Bit Assignment
• The bits can be freely assigned to
internal digital signals
channel)
0 ... 15 Mapping of C0418/1 ... C0418/16
• Configuration in C0418
• In keypad: display only (hexadecimal)
C0152
(A)
Service code Modifications only by Lenze Service!