Code table
10
Function library
10.20
L
10.20-19
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0181* Process controller
setpoint 2
(PCTRL1-SET2)
0.00 -650.00 {0.02 Hz} 650.00 ^ 10.10-5
C0182* Integration time
S–ramps
0.00 0.00 {0.01 s} 50.00 C0182 = 0.00: Linear ra mp function
generator operation
C0182 > 0.00: S- shaped ra mp function
generator (smooth)
^ 10.7-1
C0183* Diagnostics
0 No fault
Only display
g
102 TRIP active
y
p
y
104 Message ”Overvoltage ( OU)” or ”Undervoltage (
LU)” a ctive
142 Pulse inhibit
151 Quick stop active
161 DC-injection brake active
250 Warning active
C0184* Frequency
threshold
PCTRL1-I-OFF
0.0 0.0 {0.1 Hz} 25.0 If the o utput fre quency < C0184, the
I component of the process controller
will be switched off
0.0 Hz = Function not active
^ 10.10-5
C0185* Switching window
for ”Frequency
setpoint reached
(C0415/x = 4)” and
”NSET1-RFG1-I=O
(C0415/x = 5)”
0 0 {1 %} 80 C0415/x = 4 and C0415/x = 5 a re
active within a window around
NSET1-RFG1-IN
Window in C0185 = 0%:
± 0,5 % ref. to C0011
Window in C0185 > 0%:
± C0185 ref . to NSET1-RFG1-IN
C0189*
(A)
Output signal
compensator
(PCTRL1-FOLL1-OU
T)
-650.00 {0.02 Hz} 650.00 Only display
Compensator = PCTRL1-FOLL1
C0190* Main and additional
1 0 X+0
Mathematical addition of mains setpoint
v
A
setpoint
P
C
T
R
L
1
A
R
I
T
H
1
1 X+Y
p
(NSET1-NOUT) and additional setpoint
P
C
T
R
L
1
N
A
D
D
(A)
(PCTRL1-
A
RITH1)
2 X-Y
(PCTRL1-N
A
DD)
T
h
e
r
e
s
u
l
t
i
s
i
n
H
z
3
X Y
C0011
T
h
e
r
e
s
u
l
t
i
s
i
n
H
z
X = NSET1-NOUT
Y
=
P
C
T
R
L
1
-
N
A
D
D
4
X
Y
C0011
100
Y
=
P
C
T
R
L
1
-
N
A
D
D
5
X C0011
C0011
Y
C0191
(A)
Compensator
acceleration time
5.00 0.00 {0.02 s} 1300.00 Ref. to change 0 Hz ... C0011
C0192
(A)
Compensator
deceleration time
5.00 0.00 {0.02 s} 1300.00 Ref. to change C0011 ... 0 Hz
C0193
(A)
Compensator reset 5.00 0.00 {0.02 s} 1300.00 Ref. to change C0011 ... 0 Hz
Decelerate compensator to ”0”
C0194
(A)
Min. compensator
activation threshold
-200.00 -200.00 {0.01 %} 200.00 Ref. to C0011
If t he value fa lls below C0194:
Compensa t o r ”runs at C0191 o r C0192
direction - C0011
C0195
(A)
Max. compensator
activation threshold
200.00 -200.00 {0.01 %} 200.00 Ref . to C0011
If C0195 is e xceeded:
Compensa t o r ”runs at C0191 o r C0192
direction +C0011
C0196* Activation of 0
0 Auto-DCB active, if PCTRL1-SET3 < C0019
^ 10.7-6
v
auto–DCB
1 Auto-DCB active, if PCTRL1-SET3 < C0019 and
NSET1-RFG1-IN < C0019