33425 0x8291 CAN: RPDO1 me-out Keypad display: Timeout RPDO1
Cause Error type/response Remedy
RPDO3 was not received within the me-out
period set in 0x1402:005 (P542.05) or with the
sync congured.
Fault
The error type can be congured in
0x2857:001.
Eliminate EMC interferences.
Check bus load.
Related topics
4Process data objects ^ 210
33426 0x8292 CAN: RPDO2 me-out Keypad display: Timeout RPDO2
Cause Error type/response Remedy
RPDO2 was not received within the me-out
period set in 0x1401:005 (P541.05) or with the
sync congured.
Fault
The error type can be congured in
0x2857:002.
Eliminate EMC interferences.
Check bus load.
Related topics
4Process data objects ^ 210
33427 0x8293 CAN: RPDO3 me-out Keypad display: Timeout RPDO3
Cause Error type/response Remedy
RPDO1 was not received within the me-out
period set in 0x1400:005 (P540.05) or with the
sync congured.
Fault
The error type can be congured in
0x2857:003.
Eliminate EMC interferences.
Check bus load.
Related topics
4Process data objects ^ 210
33553 0x8311 Torque limit reached Keypad display: Torque limit
Cause Error type/response Remedy
Motor has reached the torque limit:
0x60E0: Posive torque limit
0x60E1: Negave torque limit
0x6072 (P326.00): Max torque
No response
The error type can be congured in
0x2D67:001 (P329.01).
Observe load requirements.
Reduce motor load.
Check set torque limits and sources for the
torque limits.
Related topics
4Motor torque monitoring ^ 170
36992 0x9080 Keypad removed Keypad display: Keypad removed
Cause Error type/response Remedy
The keypad was removed while the keypad con-
trol was acvated.
Fault
Plug on the keypad again or
acvate another control source.
Related topics
4Control source change-over ^ 345
65285 0xFF05 Safe Torque O error Keypad display: STO error
Cause Error type/response Remedy
The safety module or safety circuit of the device
was detected as being defecve.
Fault
The inverter is inhibited immediately. The
motor becomes torqueless (coasts).
The error can only be reset by mains switch-
ing.
Hardware error: it is necessary to contact the
manufacturer since the device must be