3-18 Service Manual
4025-XXX
Output Bin Sensor Test
Use this test to determine whether or not the output bin sensors are working correctly. To
run the test, select the Sensor Test operation from the OUTPUT BIN TESTS menu.
The following sensors will be listed in the bottom level menu:
• Output Bin1
• Output Bin 2
• Output Bin 3
• Output Bin 4
• Output Bin 5
• Output Bin 6
• Output Bin 7
• Output Bin 8
• Output Bin 9
• Output Bin 10
• Vertical Sensor
• Bin 10 Jam Sensor
• MBX In Sensor
• Door Interlock
To select one of the sensor above, Press either Menu> or Menu< until the desired sensor
displays. Press Select for that sensor.
Once the screen displays, you can manually actuate the sensor. When the sensor is
closed, CL displays. Likewise, when the sensor is open, OP displays. If the wrong
message displays, the sensor may be malfunctioning.
To exit the sensor test, press Return