Connector Locations 5-1
4025-XXX
5. Connector Locations
P/J Location Table
Use the table and maps in this section to locate specific P/J connectors within the printer:
1. Locate the P/J connector number in the first column of the table.
2. Locate the corresponding map and location number, such as M2-5, in the second
column.
3. With this information, go to the appropriate map.
P/J Map & Number Connected to... Other end connected to...
1 M8-16 AC Distribution PWB P/J13 Finisher Option
2 M8-1 AC Distribution PWB LVPS
3 M8-17 AC Distribution PWB P/J30 AC Driver PWB
4 M8-14 LVPS - B3 P/J1 AC Distribution PWB
5 M8-15 AC Distribution PWB - -
7 M8-2 AC Distribution PWB Main Power Switch
8 M8-3 AC Power Inlet Main Power Switch
12 M4-5 Fuser P/J31, P/J32, P/J33 AC Driver PWB
FS & T3 HVPS
P/J600
13 M1-8 Finisher AC Connector P/J1 AC Distribution PWB
20 M7-8 P/J4 P/J1 AC Distribution PWB
30 M8-10 AC Driver PWB P/J3 AC Distribution PWB
31 M8-13 AC Driver PWB P/J12 Fuser
32 M8-9 AC Driver PWB P/J12 Fuser
33 M8-12 AC Driver PWB P/J12 Fuser
34 M8-11 AC Driver PWB 220VAC Transformer
100 M2-6 Registration Sensor P/J459 I/O PWB
101 M2-8 Tray 2 Take Away Sensor P/J465 I/O PWB
102 M2-7 Tray 1 No Paper Sensor P/J459 I/O PWB
103 M2-5 Tray 1 Level Sensor P/J459 I/O PWB
104 M4-11 Fuser Exit Sensor P/J462 I/O PWB
105 M3-28 Tray 1 Size Sensor P/J461 I/O PWB