Maintenance
The actuator must be cleaned at regular intervals to remove dust and dirt and inspected for
mechanical damages or wear.
Inspect attachment points, wires, piston rod, cabinet, and plug, as well as check that the
actuator functions correctly.
To ensure that the pregreased inner tube remains lubricated, the actuator
must only be washed
down when the piston rod is fully retracted.
The actuator is a closed unit and therefore requires no internal maintenance.
In order to maintain a proper performance of the spherical eyes and to increase the resistance
against environmental wear, we strongly recommend that the spherical eyes (ball bearings)
mounted on actuators from LINAK are greased with anticorrosive grease or similar.
Repair and spare parts
Repair
Only an authorised LINAK
®
service centre should repair LINAK actuator systems. Systems to be
repaired under warranty must be sent to an authorised LINAK service centre.
In order to avoid the risk of malfunction, all actuator repairs must only be carried out by an
authorised LINAK Service shop or repairer, as special tools and parts must be used.
If a system is opened by unauthorised personel there is a risk that it may malfunction at a later date.
Spare parts
LINAK can supply spindle parts and motor parts as spare parts. Please indicate the designation from
the label when ordering spare parts from your nearest authorised LINAK dealer.
Main groups of disposal
LINAK’s products may be disposed of, possibly by dividing them into different waste groups for
recycling or combustion.
We recommend that our product is disassembled as much as possible at the disposal and that you
try to recycle it.
Chapter 5
Product Metal scrap Cable scrap Electronic scrap Plastic recycling
or combustion
LA36 X X X X

Table of Contents