but the alarm continues to occur, 
replace either the entire drive or 
the control board. Contact the 
local distributor for more 
information. 
Output Phase Loss 
 
Phase loss on the drive 
output side 
1. The output cable is not 
connected 
2. The motor winding is 
impaired 
3. The output terminal is 
loose 
4. The rated current of the 
motor being used is 5% less 
than the drive rated current 
5. An output transistor is 
impaired 
6. A single phase motor is 
activating   
1.Check the errors for wiring 
then properly connect the 
output cable 
»Correct the wiring 
2.Check the resistance which 
located between motor lines 
»If the winding is impaired, 
replace the motor 
3.Use tightening torque which 
showed in the manual in order to 
fasten the terminal 
4.Check motor capacities and the 
drive 
5.The drive cannot run a single 
phase motor 
1. Incorrect parameter 
settings 
2. Incorrect PID feedback 
wiring 
3. Feedback sensor 
malfunction 
1. Reset b5-22 and b5-23 
2. Correct the wiring 
3. Check the sensor   
1. Incorrect parameter 
settings 
2. Incorrect PID feedback 
wiring 
3. Feedback sensor 
malfunction 
1. Reset b5-12 and b5-13 
2. Correct the wiring 
3. Check the sensor   
Modbus 
Communication Error 
1. Incorrect wiring 
2. Communication data 
error caused by noise 
1. Correct the wiring 
»Check short circuits and 
disconnected cables, repair if 
necessary