193
of motor poles)
3 :Use user-defined units(defined by o1-02 and o1-03)
When the value of the maximum output frequency to be displayed with the o1-02 setting.
Digits after the decimal point is set by o1-03.
For example, when the maximum output frequency to be displayed when "200.00", can be set
as follows.
o1-02 = 20000
o1-03 = 2
o1- 01 Retain
o1- 02 User-Defined Frequency Command Setting/Display
Setpoint at maximum output frequency to be displayed。
User-Defined Frequency Command
Setting/Display
o1- 03 Frequency Command Setting/Display Decimal Places
Setting frequency command setting/display decimal places
Frequency Command Setting/Display Decimal
Places
o2 Multi-Function Selection
o2 parameters determine the functions assigned to the keys on the keypad.
o2-00 LO/RE (LOCAL/REMOTE) Key Function Selection
Enables or disables LO/RE key on the keypad
LO/RE (LOCAL/REMOTE) Key Function Selection
0 : Disabled
Switches between Local and Remote are disabled.