1 : Enabled 
Switches  between Local  and Remote  Operation  but  only during drive stop.  Switching is  not 
possible when entering a Run command. When Local mode is selected, the LED indicator on 
the LO/RE will light up.   
WARNING! Pay attention to the following situations when b1-05 (Run Command Action after Switch ) is set to 1 
(Accept Active Run Command at the New Source). 
If a run command at the new source is active, the drive will accept it and  run the motor immediately right  after 
switching from the old source to the new source. Clear all personnel from the electrical connections and the running 
machinery prior to switching command sources. Failure to comply could cause serious injury. 
Refer to Table 6.22 for the relationship between o2- 00 and b1- 05.   
Table 6.22 Relationship between LO/RE and b1-05 
Switch from Local to Remote 
Switch from Remote to Local 
The  drive  will  not  run  until  a  new  Run 
command is enterd.   
If a Run command is entered, the drive 
will start running as soon as the LO/RE 
key is pressed.     
  o2-01  STOP Key Function Selection     
Determines if the STOP key on the keypad will stop the drive when Remote is selected as the 
command source.   
STOP Key Function Selection     
0 : Disabled 
1 : Enabled 
The STOP key always stops drive operation even if the command source is not set to the 
keypad. To restart the drive,cycle the Run command if the drive has been stopped by pressing 
the STOP key. 
  o2-02  Retain     
  o2-03  Drive Capacity Selection 
Set this parameter after replacing the terminal block or drive modules.