61
5.1.3 Keypad Programming
Keypad Display Menu Structure
A. Standard setting mode: Press MENU to enter or exit the parameter group. Press ENTER,
MENU, UP, DOWN and RESET to monitor and edit settings.
B. Quick monitoring parameters mode: FN2 function keys for using quickly most of the
parameters monitored, and use the up and down keys to switch parameters want to
monitor.
C. Quick setting mode: User must assign the function to the FN1 key in advance so as to
quickly set the parameter by pressing FN1 key.
FN1
FN1
ENTER
MENU
ENTER
UP/DOWN/RESETUP/DOWN/RESET
( 1 sec )
MENU
MENU
ENTER
MENU
ENTER
UP/DOWN/RESET
UP/DOWN/RESET
( 1 sec )
U1-03 (output
frequency)
U1-06 (Main circuit
DC Voltage)
U1-05 (Output
voltage command)
U1-04 (Motor speed) AI1 (percnet)
AI2 (percent)
UP/DOWN
UP/DOWN UP/DOWN UP/DOWN UP/DOWN
MENU