EasyManua.ls Logo

LiteOn EVO 6800 Series - L6 Offset Frequency

LiteOn EVO 6800 Series
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
117
Power
supply
ON
OFF
ON ONOFFOFF
ONOFF OFF ON
L4-01 = 1
L4-01 = 0
Hold Hold
Forward
Run/ Stop
Hold
Acc./Dec.
Frequency
Command
Output
Frequency
Figure 6.40 Frequency Command Hold with Acc./Dec. Hold
· Up/Down and Up/Down 2
The frequency command will be saved when the Run command is removed, and remain active
when the drive restarts. To reset the saved frequency command to 0 Hz, enter UP or DOWN
before entering a Run command.
L6 Offset Frequency
L6- 00 to L6- 02 Offset Frequency 1 to 3
Sets the offset value as a percentage of the maximum output frequency to add to or subtract
from the frequency command. Select the offset frequency in E1-□□= 53, 54 and 55 (Offset
Frequency 1 to 3). The offset frequency will not add up being minus value and run in a reverse
direction as it is limited by the upper and lower limit.
No.
Name
Setting Range
Default
L6-00
Offset Frequency 1
-100.0 to 100.0%
0.0%
L6-01
Offset Frequency 2
-100.0 to 100.0%
0.0%
L6-02
Offset Frequency 3
-100.0 to 100.0%
0.0%