219
2. Check possible solution to
suppress the noise
A FJOG and RJOG Run
commands are received at
the same time
Check the Run command from
the external source for Fjog/Rjog
8.3 Operation Errors
Table 8.3 Error Displays, Causes, and Possible Solutions
Parameter Range
Setting Error
Parameters are set outside of
the possible setting range
1. Set the parameters to the
proper values
2. Reset the drive
Multi-Function
Input Selection
Error
1. Either of Up command and
Down command is not set
(E1-□□= 10 or 11 )
2. Either of Up command 2
and Down command 2 is not
set (E1-□□=12 or 13)
Properly assign both of the UP and
Down commands to the
multi-function input terminal.
3-Wire Sequence
Control Setting
Error
Multi-Function input
terminals S1 and S2 are
assigned to E1-□□= 2 (3-Wire
Sequence)
Do not assign multi-function input
terminals S1 and S2 to E1-□□= 2
(3-Wire Sequence)
Control Method
Selection Error
A control method that
requires a PG option card
(A1-02 = 1, 3, or 5) is
selected, but no PG card is
installed
Install a PG option card or correct
the value set to A1-02
Multi-Function
Analog Input
E3-01 and E3-07 are set to
the same value
Set different values to E3-01 and
E3-07