72
1 : Coast to Stop
When a Stop command is given, the drive will shut off its output. Then the motor will coast to
stop for the time determined by the inertia and friction.
ON
OFF
Run command
Output frequency
Motor speed
Drive output shut off
Figure 6.5 Coast to Stop
Note: After a Stop command is given, the drive will ignore any Run command entered until the minimum baseblock
time set to P2-01. Do not enter Run command until the motor has completely stopped. To restart the motor before
the complete stop, use DC braking at start (Refer to b2-02) or Speed Search (Refer to b3).
2 : DC Braking to Stop
When a Stop command is given, the drive will enter the current set to b2-01 to the motor after
waiting the minimum baseblock time set to P2-01. DC Braking to Stop significantly shorter the
stopping time compared to Coast to Stop.
Note: This function is not available in control methods for PM motors ( A1-02 = 4, 5, 6, 8).