EasyManuals Logo

Lowrance LCX-112C User Manual

Lowrance LCX-112C
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #208 background imageLoading...
Page #208 background image
198
EP-15 Fluid Level Configuration
To input Device Name:
1. Press MENU| MENU, use to select NMEA 2000 and press ENT. The
NMEA 2000 menu will appear with five options: Bus Setup, Fuel
Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight
Synchronization.
2. Highlight
BUS SETUP and press ENT, which will open the Bus Configuration
menu. A list of network devices will be at the top of the page.
3. Select a fluid level you want to rename and press
ENT. The Device
Configuration menu will appear with the Device Name dialog box
highlighted.
4. Press
ENT and use , to input the desired name for the fluid
level. Press
ENTER. Press EXIT repeatedly to get back to the main
display.
To select Tank Instance (Location):
1. Press MENU| MENU, use to select NMEA 2000 and press ENT. The
NMEA 2000 menu will appear with five options: Bus Setup, Fuel
Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight
Synchronization.
2. Highlight
BUS SETUP and press ENT, which will open the Bus
Configuration menu. A list of network devices will be at the top of the
page.
3. Select the desired fluid level and press
ENT. The Device
Configuration menu will appear.
4. Highlight
TANK INSTANCE and press ENT, which will open the Tank Instance
menu with the following options: Tank 1, Tank 2, Tank 3 and Unknown.
5. Select the desired Tank Instance (location) and press
ENT. The
following confirmation message will appear: Are you sure you wish to
change this device's configuration?
6. Highlight
YES and press ENT. Press EXIT repeatedly to get back to the
main display.
To select Fluid Type:
1. Press MENU| MENU, use to select NMEA 2000 and press ENT. The
NMEA 2000 menu will appear with five options: Bus Setup, Fuel
Management, NMEA 2000 Alarms, Waypoint Sharing and Backlight
Synchronization.
2. Highlight BUS SETUP and press ENT, which will open the Bus Configuration
menu. A list of network devices will be at the top of the page.
3. Select the desired fluid level and press
ENT. The Fluid Level Device
Configuration menu will appear.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lowrance LCX-112C and is the answer not in the manual?

Lowrance LCX-112C Specifications

General IconGeneral
BrandLowrance
ModelLCX-112C
CategorySonar
LanguageEnglish

Related product manuals