EasyManuals Logo

Lowrance LCX-112C User Manual

Lowrance LCX-112C
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #212 background imageLoading...
Page #212 background image
202
Restore Defaults command from your Port Engine Interface Advanced
Options menu, only the settings for the Port Engine Interface will be
reset to factory defaults. Other engine interfaces on the network will
not be affected.
To restore default settings:
1. Press MENU| MENU, use to select NMEA 2000 and press ENT. The NMEA
2000 menu will appear with five options: Bus Setup, Fuel Management,
NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization.
2. Highlight
BUS SETUP and press ENT.
3. Use to select the desired fluid level and press
ENT. The Device
Configuration menu will appear.
4. Highlight
ADVANCED OPTIONS and press ENT.
5. Select
RESTORE DEFAULTS and press ENT. The following message will
appear: Are you sure you wish to change this device's configuration?
6. Highlight
YES and press ENT. Press EXIT repeatedly to get back to the
main display.
NOTE:
The Suzuki Engine Interface Device Configuration menu contains
two Engine Trim calibration commands, which will be addressed in
the next segment of this section, Calibrating EP Sensors.
Calibrating EP Sensors
The factory calibration settings for the EP-10 Fuel Flow, EP-15 Fluid
Level and Suzuki Engine Interface should be adequate for the majority
of applications, so calibration will not be necessary in most cases.
EP-10 Fuel Flow Calibration
The default calibration for the EP-10 Fuel Flow is adequate in most
cases, but if Fuel Used readings are off by more than 3 percent,
calibration is recommended.
To check fuel flow accuracy:
Select Fuel Used to be shown as Overlay Data on your unit's main display.
Refer to the Overlay Data segment of this manual for instructions on how
to select Fuel Used data as Overlay Data.
1. After selecting Fuel Used as overlay data, fill up your tank and press
MENU|MENU.
2. Select
NMEA 2000 and press ENT.
3. Highlight
FUEL MANAGEMENT and press ENT. Select TANK LOCATION and press ENT.
4. Use to select the location (Port, Center or Starboard) of the fuel
flow you want to calibrate and press
ENT.
5. Highlight
FILL TANK and press ENT. The following confirmation
message will appear: Are you sure you wish to Fill Tank?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lowrance LCX-112C and is the answer not in the manual?

Lowrance LCX-112C Specifications

General IconGeneral
BrandLowrance
ModelLCX-112C
CategorySonar
LanguageEnglish

Related product manuals