Chapter 10 Troubleshooting 
 
10-6 
10.2.2 Error code 
 
It is brief and can monitor a communication module error through XG5000.   
Click [Onlie] -> [Communication module setting] -> [System diagnosis[]   
Right click FEnet module -> [Status by service] -> [P2P Service] 
When you use the E-mail service, please perform reference of E-mail error code. 
 
P2P 
0x0001  Modbus receive frame error 
0x0002  Modbus size error 
0x0006  Disconnect error 
0x0010  Parameter download error 
0x0013  Parameter structure error 
0x0015  P2P Event send error 
0x0016  P2P Event receive error 
0x0017  P2P connection error 
0x0051  Channel connection overflow 
0x0062  Channel setting error 
0x00F0  Internal buffer allotment error 
0xFF00  User defined data send error(user defined frame) 
0xFF01  User defined frame event receive error 
0xFFD7  Internal data send overflow 
0xFFEB  Internal interlock error 
0xFFFF 
When it request connection for server setting, User defined send frame size 
error 
E-mail 
0x0001  Email address error 
0x0002  Email file 
0x0003  Email server login error 
0x0005  Email send error 
0x0007  Email Disable 
0x5D52  Email download error 
0xFFCE  Internal send buffer timeout error 
0xFFD6  Internal send buffer reset error 
0xFFD9  Internal send buffer delete error 
0xFFEA  Internal send buffer size error 
0xFFE8  Internal send buffer interlock error 
0xFFF1  Internal send buffer pointer error 
0xFFF2  Internal send buffer error