Engineering Guide CDA3000
3-67
3  Selection of inverter module
DE
EN
1
2
3
4
5
6
7
A
Break-away and acceleration torques dependent on motor con-
trol method
The table above indicates what typical torque is available on the motor
shaft of an asynchronous machine when the machine is driven by a
CDA3000 inverter module. The maximum motor rated current is limited by
the inverter module to 2 x I
N-Motor
.
For data relating to the servomotors refer to section 2.5.2.
Property
VFC
Voltage 
Frequency 
Control
SFC
Sensorless Flux 
Control
FOR
Field-Oriented 
Regulation
Break-away torque
1)
 with standard 
motor (U
N
 = 400 V)
1.6 x M
N
1.8 x M
N
2 x M
N
Break-away torque
1)
 with servomo-
tor (U
N
 = 330 V)
2.5 x M
N
2.6 x M
N
2.8 x M
N
Acceleration torque
1)
 with standard 
motor (U
N
 = 400 V)
1,2 x M
N
1.8 x M
N
2 x M
N
Acceleration torque
1)
 with servomo-
tor (U
N
 = 330 V)
1.6 x M
N
1.8 x M
N
2 x M
N
1)
 I
Inverter
 = 2 x I
Motor
Table 3.32 Break-away and acceleration torques