3.1 Technical data Type codes of inverter modules
*) The design code is separated by a comma. A maximum of 5 designs 
can be suffixed.
Single-phase inverter modules 
Design code
*)
 
Hardware default configuration
Cooling method:
C = Cold plate
W= Wall mounting
D = Push-through heat sink
Continuous output current
Mains voltage:
2  =  1 x 230 V -20% +15%
4  =  3 x 460 V -25% +10%
Inverter module series
CD
A
3x x
x
x
X
x x
.
.
,
x
x
Inverter module
Rec. 4-pole 
standard motor
Rated 
current
Peak current
1)
Power loss Device output
CDA32.003,Cx.x 0.375 kW 2.4 A 4.3 A 25 W 0.95 kVA
CDA32.004,Cx.x
0.75 kW 4.0 A 7.2 A 45 W 1.5 kVA
CDA32.006,Cx.x 1.1 kW 5.5 A 9.9 A 75 W 2.1 kVA
CDA32.008,Cx.x
1.5 kW 7.1 A 12.8 A 95 W 2.7 kVA
1) 1.8 x I
N
 for 30 s Mains voltage 1 x 230 V -20 % +15 %
Mains frequency 50/60 Hz ±10 %
Cooling air temperature 
(1000 m above MSL) 45 °C at 4 kHz
Power stage switching frequency 4, 8, 16 kHz
Output frequency 0 ... 1600 Hz
Table 3.1 Overview of inverter modules for 230 V systems