5-14
Engineering Guide CDA3000
5 Communication and user modules
There are two ways of connecting LUST drive units to PROFIBUS-DP:
1) PROFIBUS-DP Gateway CP-DP 1
− Cost-optimized PROFIBUS interface for interconnection of
several (up to 10) drive units on PROFIBUS-DP
− Drive units from the CDA3000, MC7000 and CDA3000 product
families can be run together on a PROFIBUS-DP Gateway
− For connection to the PROFIBUS-DP Gateway the drive units
must be fitted with the CAN
Lust
interface.
2) PROFIBUS-DP module
− PROFIBUS-DP expansion module for CDA3000
− Optimized for connection of a CDA3000 inverter module to the
PROFIBUS-DP
− Supports the expanded PROFIBUS-DP functions in accordance
with Directive 2.084
5.4.1 Interconnection
of LUST drive
units with the
PROFIBUS-DP
Gateway
The PROFIBUS-DP Gateway connects up to 10 LUST drive units to the
PROFIBUS-DP. The drives are thereby turned into full-scale PROFIBUS-
DP stations.
Figure 5.8 PROFIBUS Gateway type DP-CPx
119 mm
114.5 mm
99 mm
22.5 mm