Engineering Guide CDA3000
6-13
6 Selection of supplementary components
DE
EN
1
2
3
4
5
6
7
A
6.3.2 Assignment to
inverter modules
CDA3000
Braking resistor for inverter module
For more detailed information on the dimensioning of the braking resis-
tors See section 3.3.8.
Tech.data
Order ref.
Resistance
[
±10 %]
Cont. braking
power [W]
Peak braking power [W]
Protection
390 VDC
1)
750 VDC
2)
BR-270.02, 540 270 150 560 2080 IP54
BR-270.03, 541 270 300 560 2080 IP54
BR-160.02, 540 160 150 950 3500 IP54
BR-160.03, 541 160 300 950 3500 IP54
BR-090.03, 541 90 300 1690 6250 IP54
BR-090.10, 201 90 1000 1690 6250 IP20
BR-090.10, 541 90 1000 1690 6250 IP54
BR-042.20, 201 42 2000 - 13390 IP20
BR-042.20, 541 42 2000 - 13390 IP54
BR-015.60, 541 15 6000 - 37500 IP20
BR-010.80, 541 10 8000 - 37500 IP54
1) 1 x 230 V mains connection -20%, +15%
2) 3 x 460 V mains connection -25%, +10%
Table 6.11 Technical data