EasyManua.ls Logo

Lust CDA3000 - Permissible Motor Cable Length with Internal RFI Filter

Lust CDA3000
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Engineering Guide CDA3000
6-15
6 Selection of supplementary components
DE
EN
1
2
3
4
5
6
7
A
6.4.2 Permissible
motor cable
length with
internal RFI filter
[A] [B] [C] [D] [E] [F]
4 kHz power stage clock
frequency
8 kHz 8 kHz power stage contact
frequency
16 kHz power stage contact
frequency
Inverter
module
Rec. 4-pole
standard
motor
[kW]
With integral
mains filter
With [A] and
line choke U
K
=4%
With integral
mains filter
With [C] and
line choke U
K
=4%
With integral
mains filter
With [E] and line
choke U
K
=4%
Class
A
[m]
1)
Class
B
[m]
1)
Class
A
[m]
1)
Class
B
[m]
1)
Class
A
[m]
1)
Class
B
[m]
1)
Class
A
[m]
1)
Class
B
[m]
1)
Class
A
[m]
1)
Class
B
[m]
1)
Class
A
[m]
1)
Class
B
[m]
1)
CDA32.003 0.375 kW 25 10 25 10 25 10 25 10 25 - 25 -
CDA32.004 0.75 kW
25 10 25 10 25 10 25 10 25 - 25 -
CDA32.006 1.1 kW
15 10 15 10 25 15 25 15 25 - 25 -
CDA32.008 1.5 kW
15 15 15 15 25 15 25 15 25 - 25 -
CDA34.003 0.75 kW
15 15 25 15 25 10 25 15 25 - 25 -
CDA34.004 1.1 kW
15 15 25 15 25 10 25 15 25 - 25 -
CDA34.005 1.5 kW
15 15 25 15 25 10 25 15 25 - 25 -
CDA34.006 2.2 kW
15 15 25 15 25 10 25 10 25 - 25 -
CDA34.008 3.0 kW
25 10 25 15 25 - 25 10 25 - 25 -
CDA34.010 4.0 kW
25 10 25 15 25 - 25 10 25 - 25 -
CDA34.014 5.5 kW
25 10 25 15 25 10 25 25 15 - 25 15
CDA34.017 7.5 kW
25 10 25 15 25 10 25 25 15 - 25 15
1) Maximum permissible motor cable length at which the standard is maintained
Table 6.14 Permissible motor cable length with integral mains filter
dependent on standard EN 55011 A/B