4-2
Engineering Guide CDA3000
4  Software functions
4.1 User interface 
and data 
structure
This section describes handling of the data sets and parameter setting of
the CDA3000 inverter module.
Users can adapt the “active data set” of an inverter module to the specific
application by way of the K
EYPAD KP200 control unit or the user-friendly
D
RIVEMANAGER PC user software.
4.1.1 Data structure
Individual parameters, parameter groups (subject areas) or complete pre-
set parameter sets can be selected. The complete preset parameter set
is called an application data set.
Subject areas
For ease of handling the parameters of the CDA3000 inverter module are
assembled into groups. The parameter groups are called subject areas,
and permit function-oriented operation of the inverter module (See Figure
4.1).
Application data set
Application data sets are complete preset parameter sets for handling a
wide variety of movement tasks (See Figure 4.2).
Loading an application data set into the RAM automatically configures the
inverter module. All subject areas and the signal processing inputs and
outputs are automatically preset to the desired solution.
Use of the application data sets simplifies and speeds up commissioning
of the inverter module and thus the movement solution.
Available application data sets
➢ “Traction and lifting drive” for typical applications such as 
conveyor belt, rack, trolley, spindle and lifting gear drives
➢ “Rotational drive” for typical applications such as spindle, 
extruder and winding drives or centrifuges
➢ “Field bus operation” for integration of the inverter system into a 
network via CANLust, CANopen or PROFIBUS-DP
➢ “Master-/Slave operation” for reference coupling of several inverter 
modules