4-8
Engineering Guide CDA3000
4  Software functions
3. Input of motor data
3.1 Read motor data from rating plate of motor
Figure 4.3 Motor rating plate
3.2 Call up the individual motor parameters and enter the read values
Parameter Setting Function
      MOTYP ASM Motor type = asynchronous machine
(1)  MOPNM 1.5 kW Motor rated power
(2)  MOVNM 400 V Motor rated voltage
(3)  MOFN 50 Hz Motor rated frequency
(4)  MOSNM 1450 rpm Motor nominal speed
(5)  MOCNM 6 A Motor rated current
(6)  MOCOS 0.8
cos 
ϕ of motor
Table 4.3 Parameters for the motor data
400 V
1.5 kW
1450 rpm
6.0 A
cos 
j
 = 0.8
50 Hz
(1)
(2)
(3)(4)
(5)
(6)