Engineering Guide CDA3000
4-51
4 Software functions
DE
EN
1
2
3
4
5
6
7
A
(ASTER=BUS_1)
Field bus operation (configuration 9)
Figure 4.40 Control terminal configuration with ASTER=BUS_2
H1 H2 H3
X4
X2
X1
X3
ANTRIEBSTECHNIK
D-35633 Lahnau
L3
U
V
W
RB+
RB
L-
L1
L2
12345 161718192011 12 13 14 15678910
ACHTUNG
Kondensatorent-
ladezeit >3 Min.
Betriebsanleitung
beachten!
WARNING
capacitor disscharge
time >3 minutes.
Pay attention to the
operation manual!
ATTENTION
temps de decharge
du condensteur
>3 min. observer le
mode dèmploi!
!
X10
X11
X12
1
2
Function Application
Control of the inverter module over
the field bus
All digital inputs and outputs can be
set and read over the bus.
Traction and lifting drive
Rotational drive
X2 Function (1...10)
1 Reference voltage 10V, 10mA
2 Analog input 1
3 Analog input 2
4 Analog ground
5 Analog output
6
Auxiliary voltage 24 V max.
200 mA
7
8 Power stage hardware enable
9 Digital input 1
10 Digital input 2
11 Digital input 3
12 Digital input 4
13 Auxiliary voltage 24 V
14 Digital ground
15 Digital output 1:
16 Digital output 2:
17 Digital ground
18 Digital output 3:
19 Relay with
20 changeover contact
X3 Function
1
Motor PTC connection
Function inactive
2
ENPO

Table of Contents