Pilot’s Guide 5-7
Troubleshooting
Table 5-2: Troubleshooting for the Panel Mount Lynx NGT-9000
SyMPtoM cauSe/corrective actionS
No targets are shown on
the traffic screen.
Ownship data is
displayed.
A “Traffic Unavailable” or
“Traffic Failed” indication
is being displayed.
If installed, ADS-B Fail
lamp is OFF.
The aircraft is not in an ADS-B (UAT
/ 1090ES) coverage area, or the
targets are not transmitting ADS-B
data, or the ground station is not
transmitting ADS-B data.
The symptoms are normal if the
target or ground station are not
transmitting ADS-B.
The target or ground station
needs to be within line-of-site
range.
At next power cycle if symptoms
persist contact L-3 Field Service
before removal of the unit or
other equipment.
1.
2.
3.
No targets are shown on
the traffic display.
Ownship data may or
may not be displayed on
the weather display.
The MSG window is
showing and functions
are showing as failed or
degraded.
Possible hardware problem with the
Lynx NGT-9000.
At next power cycle if symptoms
persist contact L-3 Field Service
before removal of the unit or other
equipment.
No data on the weather
display.
If installed, ADS-B Fail
lamp is OFF.
The FIS-B data is not being trans-
mitted to the weather display.
No ground station is in range.
The ground station may not
provide FIS-B service.
At next power cycle if symptoms
persist within a known FIS-B
service area, then contact L-3
Field Service before removal of
the unit or other equipment.
1.
2.
3.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lynx NGT-9000 Series and is the answer not in the manual?

Lynx NGT-9000 Series Specifications

General IconGeneral
TypeAvionics Display
DisplayLCD
Operating Temperature-20°C to +55°C
InterfaceARINC 429, RS-232