Boom extension
4.2 Description of the rigging work
4 - 14 3 112 441 en Lattice extension operating instructions
GMK 4100/4100-L/5095
11.01.2008
Connection to
the swing-away
lattice
(A) – Establishing the connection
Remove the long ends (2) from the holders (4)
in section 3.
Lay the long ends (2) through section 3 as
far forward as possible to section 1.
Remove the hoses (3) from the holder (1) in
section 1.
Remove the protective caps and connect the
hoses (3) with the long ends (2).
Secure the hose lines at the holder (4) in
section 3 to ensure they do not hang out
during operation.
(B) – Disconnecting the connection
Disconnect the hoses (3) from the long ends (2).
Close the short ends and the hoses with the protective caps.
Secure the hoses (3) at the holder (1) in section 1.
Lay the long ends (2) to the rear through section 3.
Secure the long ends (2) to the holders (4) in section 3 to prevent them
from hanging out during transport.