Pre-Installation Inspection:
Correct model Correct capacity
Correct platform size Correct options
Correct manuals & decals
Structural Inspection:
Liftgate is centered on vehicle rear door &
mounted per dimensions in this manual.
Pump box is mounted securely.
All installation welds are done per instructions
in this manual.
All roll pins, bolts & fasteners on liftgate
are tight.
All hardware & fasteners, used to secure
liftgate to vehicle body, are tight.
Ensure platform ramp touches ground when
runner is 1” above ground. The main platform
& ipover surfaces should be level to one
another and rest evenly when touching the
ground.
Verify runner slide pads are in adjustment per
STEP 18 in this manual.
Hydraulic Inspection:
Fluid is at correct level (See OPTIMIZE HY
DRAULIC FLUID LEVEL step in this manual.)
No leaks from hydraulic ttings in pump box
No leaks from hydraulic line connections
Electrical Inspection:
Power/charge plug and terminals are clean &
tight.
Individual wire connections are tight.
Circuit breaker (150A) is installed in battery box
(if equipped) or by truck/tractor battery.
Batteries are fully charged, all cable
connections are tight & tiedowns are tight.
Solenoid wiring connections are tight.
Wiring harness connections are tight.
Electrical cable connections are tight &
secured clear of moving parts & sharp edges.
Model:______________________ Date: ____________________
Serial Number: _______________ Technician: _______________
Operation Inspection:
Liftgate operates correctly using all main &
optional control switches.
All BMR: Platform unfolds in 5 to 7 sec.
All BMR: Platform can be lowered onto the
bottom stop position for dock loading, and 1”
below the threshhold plate.
All BMR: platform folds in 5 to 7 sec.
BMR-35 or -44 only
Unloaded platform lowers in 8 to 20 sec.
Unloaded platform raises in 9 to 21 sec.
BMR-55 or -66 only
Unloaded platform lowers in 12 to 23 sec.
Unloaded platform raises in 13 to 26 sec.
All BMR: Unloaded platform raises and lowers
evenly in GD and PD modes. Maximum 1”
difference of runners from side to side.
All BMR: Platform stores securely behind both
column wedges.
Cycle counter indicates total number of up and
down cycles and adds 1 more count each time
platform is raised and lowered.
Decals in correct location and legible.
Verify all lights are operational
Platform lights turn ON when platform is un-
folded, and turn OFF when platform is stowed.
Taillights, stop lights, turn lights, and backup
lights turn ON and OFF correctly.
NOTE: The following times are for 56” bed
height, aluminum platform and
ipover, 85” W x 42” + 42” L, Exxon
Univis HVI-13 oil, & temperature at
70°F. Times are for reference only
and may vary for larger platforms,
smaller platforms, steel platforms, or
temperature changes.
PRE-DELIVERY INSPECTION FORM
Important! This pre-delivery checklist is to aid the installer in con rming the proper installation of
this Maxon product. It is not a comprehensive list and does not replace the use of the installation
manual. The installer is responsible for following all instructions in the installation manual.

Table of Contents

Related product manuals